PICU DRUG INFORMATION
Adenosine
Antiarrhythmic
SVT IV/IO: Initially: 0.1 mg/kg (maximum: 6 mg/dose) if no response in 2 min: 0.2 mg/kg (maximum: 12 mg/dose)
Not effective for atrial fibrillation/flutter or ventricular fibrillation. Adverse effects such as dyspnea, arrhythmias, bradycardia, flushing, sinus and AV block are very common but are usually transient due to short (10 seconds) half-life of drug.
Administration: Give rapid IV bolus followed by rapid saline flush.
Pharmacology: Slows A-V node conduction by blocking AV node re-entry pathways and suppressing atrial and Purkinjie tissue automaticity. Very short t ½ (10 seconds).
Updated: 12/21/2022
Disclaimer: This document has been created specifically for Hamilton Health Sciences (HHS) to use for its own patients and the information contained herein may not be applicable or relevant to other health care organizations. This document is for informational purposes only and is not intended to be a substitute for medical or clinical advice from a qualified health care professional. HHS makes no representations or warranties as to the accuracy of the information. This material is current only to the date listed. This material is the intellectual property of HHS and may not be shared, duplicated, or distributed further without the consent of HHS. HHS assumes no liability for the use of this information by the recipient.
| |